The
B oatA nchorM anualA rchivePath: /paccomm/ |
This is the BAMA archive. These manuals are available for download and free of charge. Do not be tricked into paying for a manual that is available here for free.
I am now accepting new manuals for inclusion in this archive. Contact and submission information below
Command and Function Reference for PacComm Firmware ------------------------------------------------------------------------- Upper case portion of command is the shortest useable form. Default values are in parenthesis. Call string = call #1[-n] [via call #2[-n] [call #3 [-n] ... [call #9 [-n]] where -n can be 0 thru 15 Notes: [1] Not available on all models [2] Default varies [3] Export only [4] PMS user only [5] PMS user & SysOp [6] Identifies Health Counters and Indicators [7] Identifies Functions Command Argument Description ?APRS? [7] When found in the data field of a received frame, TNC initiates transmission of GPS capture buffers (see LOC) 3rdparty ON|OFf Allow PMS messages to other than SysOp 8bitconv ON|OFf Pass or strip high-order bit in CONV mode ACKprior ON|OFf Enable prioritized acknowledgements ACKTime n = 0-250 (14) Sets delay for prioritized acknowledgement ADrdisp ON|OFf Displays addresses for monitored frames AMonth ON|OFf Select alphabetic or numeric month in date ASyrxovr [6] Async. receive overflow error counter ASYFrerrr [6] Async. framing error counter ASYQover [6] Async. overflow error counter AUTOFwd ON|OFf Enable automatic forwarding of PMS messages AUtolf ON|OFf Send linefeed to terminal after each CR AWlenn 7 or 8 Number of bits in each byte sent to terminal Ax2512v2 ON|OFf Select Ver. 2.0 (ON) or 1.0 of AX.25 protocol AXDelay n = 0-180 Extra keyup delay for voice rptr (n * 0.1 sec) AXHang n = 0-20 Voice repeater hang time (n * 0.1 sec) BAud [1] Sets terminal and radio baud rates BBfailed none bbRAM failure message BBSmsgs ON|OFf Alter message display for BBS applications Beacon E|A n=0-250 Beacon timing/mode (E|A)(0-250 *10 sec) BSLot n = 0-59 (60) Value indicates second to be used, 60 disables beacon slotting function BESLot ON|OFf (ON)Selects TDMA beacon timing (OFF) selects conventional timing BKondel ON|OFf Select (ON) backspace or del for DEL key BRAange [1] n = 1-4 (3) Sets beacon timer interval BReak ON|OFf Enable response to BREAK signal BSUBSLOT n = 1-9 (0) Value indicates tenth of a second slot to be used, 0 disables BText text Text to be sent as beacon (max 120 chars). BT % clears this field. BUdlist ON|OFf Treat LCALLS as the only stations to monitor Bye [4] none PMS user command to exit the PMS CALibra [1] none Enable calibrate mode for the built-in modem CALSet [1] n = 0-65335 Sets parameters for CAL "LEDcounter" CANline n = 0-$7F ($18 ^X) Sets Cancel-line character CANPac n = 0-$7F ($19 ^X) Sets Cancel-packet character CBell ON|OFf Enable (ON) connect bell on terminal CHeck n = 0-250 (12) Connection check time (n * 10 sec) CHECKV1 ON|OFf Enables Checktime for AX.25L2V1 CLKadj n = 0-65335 Real time clock adjustment (slows clock) CLKSet ON|OFf Enable clock setting by BBS connection CMdtime n = 0-255 (1) Sets the transparent mode timeout value CMSg ON|OFf Enable the connect message function CMSGDisc ON|OFf Enable forced disconnect after Connect Msg COMmand n = 0-$7F ($03) Set CONV to CMD mode entry character CONMode CONV|TR Mode to enter when connection occurs Connect Call string Open a connection via optional repeaters CONOk ON|OFf Enable accepting connections CONPerm ON|OFf Select temporary or permanent connection CONRPT ON|OFf Xmits GPS capture buffers (LTEXT, L1, L2, L3text), STEXT (if not blank), and CTEXT (if CMSG is ON) , when station connects to TNC CONStamp ON|OFf Print date and time on connect messages CONVerse none Enter CONV mode from CMD mode (alt = K) CPactime ON|OFf Enable CONV mode timed packet dispatch CR ON|OFf Select appending a CR to each data packet CRAfter ON|OFf Add CR after monitored frame CStatus none Display the status of all streams CText text Connect Message Text (120 characters). CT % clears this field. CWid [3] E|A n=0-250 CWID frequency/mode (E|A)(0-250 *100 sec) CWIdtext [3] text Up to 32 alphanumeric characters for CWID CWLen [3] n = 1-9 (6) Set CWID wpm (9=13, 6=20, 3=40) DAytime yymmddhhmmss Set or display date and time DAYUsa ON|OFf [2]Date format mm/dd/yy (ON) or dd-mm-yy DEAdtime n = 0-250 (20) Sets the length of the slot used in SLOTS DELete ON|OFf Select BS char: BS($08)(OFF) or DEL($7F) DIGI-NOT-OWN [7] This function causes the TNC to never digipeat a frame that was originated with that TNC's MYCALL. It prevents multiple repeating of the same frame due to multiple alias callsigns. DIGI-ONCE [7] This function causes the TNC to only digipeat a frame once when it finds its MYCALL in the path and the "has been repeated" bit is on. DIGIpeat n = 0-8 0= DIGIpeat OFF (the old DIGI N) 1=DIGIpeat ON and DIGI-SWAP enabled 2=DIGIpeat ON and DIGI-NOT-OWN enabled 3=DIGIpeat ON, DIGI-NOT-OWN and DIGI-SWAP enabled 4=DIGIpeat ON and DIGI-ONCE enabled 5=DIGIpeat ON , DIGI-SWAP and DIGI-ONCE enabled 6=DIGIpeat ON, DIGI-NOT-OWN and DIGI-ONCE enabled 7=DIGIpeat ON, DIGI-SWAP, DIGI-NOT-OWN, and DIGI-ONCE enabled (Default) 8=DIGIpeat ON (like the old DIGI Y with no new features) DIGISent [6] none Digipeated frames sent counter DIGI-SWAP [7] This function causes the TNC to replace the alias call in a frame with the MYCALL when the TNC digipeats a frame. This allows subsequent stations to know the real path taken by the frame so that a reverse addressed frame may be sent back. It also puts valid packet station identification in the frame. Disconnect none Teardown connection on current stream DISPlay A,B,C,G,H,I,L,M,P,T Display ALL or selected parameters (i.e G = GPS parameters, etc.) DWait n = 0-250 (0) Extra digipeater delay (n * 10 msec) Echo ON|OFf Echo parameters typed on keyboard EBEacon ON|OFf Sends BTEXT to the terminal port vice RF port EDithdr [5] to call, @ call Edit PMS message 'to' or '@ BBS' callsigns ELOc ON|OFf Select async or RF location beacon EScape ON|OFf Set ESC character ($1B)(OFF) or ($24)(ON) FIrmrnr ON|OFf Reduce frequent polling of busy packet stations FIXType n =0-4 (1) Type of search to indicate good GPS fix Flow ON|OFf Inhibit output to terminal while user is typing FOrward [5] Msg # Cause PMS Msg # to be reverse forwarded FNPms callsign [via callsign #2] Force PMS forward via node FPms callsign [via callsign #2] Force PMS forwarding FRack n = 1-15 (3) Set time to wait for packet ack FSCreen ON|OFf Select four column DISPLAY presentation FUllduplex ON|OFf Select simplex or duplex mode GPS ON|OFf Configure the serial port for a GPS receiver GPSExit none (1) Sets character to exit GPS scan mode GPSItext blank Command string sent to GPS if GPS=ON. GPSI % clears this field. GPSTExt $GPGGA Fill-in GPS NMEA-183 string to be used. GPSTE % clears this field. GPSType [1] n = 0-8 Selects type of GPS string format HEaderli ON|OFf Header and text on same/separate lines HEALled ON|OFf Normal/software test by CON/STA LEDs Help or ? [4] none PMS Help display for the PMS user HId ON|OFf Enable ID packet every 9.5 minutes HOMebbs callsign Callsign of 'Home BBS' serving you PMS HOvrerr [6] none HDLC over run error counter HUndrerr [6] none HDLC under run error counter Id none Send ID packet (UI) frame via UNproto path Jlog [4] none Displays the MHEARD for the PMS user K none Alternative form of the CONV command KIll or Kill [4] n Kill (delete) message number n from PMS KILONFWD ON|OFf Kill (delete) PMS messages after forwarding KISs ON|OFf Select KISS mode. Must follow by RESTART KM [5] none Kill all PMS messages addressed to my callsign LCAlls call # 1-8 Callsigns to receive or ignore (see BUDLIST ) LCok ON|OFf Convert lower to UPPER case (async) LCStream ON|OFf Allow STREAM ID char to be lower case LFadd ON|OFf Add Line Feed to each CR sent to terminal LFIgnore ON|OFf Filter embedded linefeeds in received data LGEtchar n = 0-$7F ($00) Set character to trigger async LTEXT dump ** LGEtchar should be set to $05 for use with APRS Release 74d and later** LG1text none String accepted from GPS for PMS history log. LG1 % clears this field. LG2text none String accepted from GPS for PMS history log. LG2 % clears this field. LG3text none String accepted from GPS for PMS history log. LG3 % clears this field. List [5] none List the 10 most recent PMS messages LOCation E|A n =0-250 Position report timing/mode (E|A)(0-250 *10sec) LOGonmsg ON|OFf Enable standard PMS logon message LPATH call string (GPS) Path & address to send UI location frames LTEXT Waiting Data from GPSString accepted from GPS to be sent by LOC command. LTEXT % clears this field. L1text Waiting Data from GPS String accepted from GPS to be sent by LOC command. L1 % clears this field. L2text Waiting Data from GPS String accepted from GPS to be sent by LOC command. L2 % clears this field. L3text Waiting Data from GPS String accepted from GPS to be sent by LOC command. L3 % clears this field. LSLOT n = 0-59 (60) Selects second location beacon is sent LSLOTMIN n = 0-59 (60) Selects minute LSLOT timing applies to LSUBSLOT none Divides LSLOT into two time slots MAll ON|OFf Monitor connected frames and UI frames MAXframe [2] n = 1-7 (4) Number of outstanding frames allowed MCOM ON|OFf Display data/all (CON/DIS/UA/DM) frames MCon ON|OFf Monitor UI frames while connected MFilter n = 0-$7F Four characters to purge from monitored data MHClear none Clear the Calls Heard list MHeard none Shows calls heard and date/time (if clock set) MIne or Mine [4] none List messages to/from callsign MKiss none Immediate entry into KISS mode Monitor ON|OFf Monitor ON - see BUD, MALL, MCON, MST MRpt ON|OFf Display monitored digipeater paths MSGHdr ON|OFf Add message header to forwarded messages MSGRoute ON|OFf Deletes most BBS routing history in PMS msg MStamp ON|OFf Select time stamping of monitored frames MYAlias call [-n](none) Alternate callsign (for digipeater use ) MY1alias call [-n](none) Alternate callsign (for digipeater use) MY2alias call [-n](none) Alternate callsign (for digipeater use) MY3alias call [-n](none) Alternate callsign (for digipeater use) MYcall call [-n](NOCALL) Station callsign for ID and linking MYPcall call [-n](none) PMS callsign (different than MYCALL) MYRose call [-n] Callsign of local ROSE switch NEwmode ON|OFf Select timing and method of changing modes NODetext text (blank) Callsign string for FNPMS command. NOD % clears this field. NOmode ON|OFf Allow explicit mode change only NUcr ON|OFf Select sending NULLS ($00) after a CR NULf ON|OFf Select sending NULLS ($00) after a LF NULLs n = 0-30 # of nulls sent if NUcr or NULf enabled Paclen [2] n = 0-255 (128) Number of bytes of data in a frame PACTime E|A n = 0-250 (A10) TRANS mode timer (n * 100 ms) PARity n = 0-3 Serial parity: 0/2=none,1=odd, 3=even PASs n = 0-$7F ($16^V) Sets the value of the PASS char PASSAll ON|OFf Display frames with valid CRC or all frames PASSWD [1] (PASSWORD) Remote Call password (19 char maximum) UPPER/lower case matters! PErsist n = 0-255 (63) Set threshold for KISS retry probability PIdchec ON|OFf Select allprotocol ID or PID F0 PMs ON|OFf Enable Personal Message System PMSConn [6] none PMS connection counter POrt [1] 1|2 Set radio port, modem tones,baud rate PPersist ON|OFf Selects channel access timing method PPRint [1] Msg #(s) Print PMS message(s) via printer port PRefix ($00) Specifies char. added to monitored frames PRAutolf [1] ON|OFf Add line feed to each CR set to printer PRInt [1] ON|OFf Enable printer port operation PRPage [1] ON|OFf Enable control of printer pagination PRPDisc [1] ON|OFf Send form feed char upon DISCONNECT PRPGln [1] n = 1-99 (60) # of lines per page if PRPAGE is ON PRTTOFf [1] n = 0-$7F($0F^O) Disable print char (if PRTTgl ON) PRTTON [1] n = 0-$7F $10(^P) Enable print char (if PRTTgl ON) PRTTgl [1] ON|OFf Set print control via PRTTON/PRTTOFF PRTUifra [1] ON|OFf Send monitored frames to printer port RCVDFrmr [6] none Received frame rejection counter RCVDIfra [6] none Received frame counter RCVDRej [6] none Received reject frame counter RCVDSabm [6] none Received SABM frame counter RCVDRNr [6] none Received RNR frame counter Read [5] # Display PMS message # to operator or user REConnect call string Reestablish a connection via a new path REDisplay n = 0-$7F ($12^R) Set character to print the input buffer REMote ON|OFf Enables remote operation REMSysop ON|OFf Enable Sysop functions for remote operator RENUmber none Re-number all PMS messages starting with 1 RESET none Reset TNC and set bbRAM to default parameters RESptime n = 0-250 Select the delay for sending an ACK (n * 100ms) RESTART none Reset TNC using user supplied parameters REtry n = 0-15(10) Max number of retries (0 = infinity) RFNPms callsign [via callsign #2] Force PMS rev forward via node RFPms callsign [via callsign #2] Force PMS reverse forwarding RTCSync ON|OFf Syncs real time clock with GPS time RXAbort none (1) Receive abort counter RXblock ON|OFf Format TNC data for computer processing RXCount [6] none Received frame counter RXErrors [6] none Received error counter RXLenerr [6] none Received length error counter RXResync [6] none Receive re-synchronization counter Screelen n = 0-255 (0) Select line length (screen width) for terminal SEND [4] or SP [5]callsign Creates a message to from user SB [5] callsign Create a bulletin message SEND or SP [5] callsign Create a message to from MYPcall SEndpac n = 0-$7F ($0D CR) Select the character which sends frame SENTFrmr [6] none Frame rejects sent counter SENTIfra [6] none Information frames sent counter SENTRej [6] none Frames rejects sent counter SENTRNr [6] none RNR frames sent counter SLOts n = 0-127 (2) Number of slots is SLOTS timing SLottime n (50) Set KISS rigor in accessing channel SR [5] Msg # Enter reply message to callsign of Msg # in PMS ST [5] callsign Enter a 'TRAFFIC' msg to in PMS STArt n = 0-$7F ($11^Q) Set XON char for data to the terminal STATus none Query connection and frame acknowledgement status STExt text PMS custom sign-on msg text (max 80 chars) STOp n = 0-$7F ($13^S) Set XOFF char for data to terminal STREAMCa ON|OFf Select showing the callsign after stream identification. STREAMDb ON|OFf Print the stream switch character once/twice (||A) STReamsw n = 0-$FF ($7C ) Set the character to use to change streams TKILlok ON|OFf Allows any PMS user to kill NTS messages TRACe ON|OFf Select the hexadecimal trace mode Trans none Place the TNC in TRANSPARENT mode TRFlow ON|OFf Enable flow control to the terminal (TRANS mode) TRIes n = 0-15 Set or display the current retry counter TXCount [6] none Frames transmitted counter TXdelay n = 0-120 (15) Keying delay for the transmitter (n * 10ms) TXDELAYC n = 0-120 (12) Number of character times of extra TXD TXFlow ON|OFf Enable flow control to the TNC (TRANS mode) TXQovflw [6] none Transmit queue overflow counter TXTmo [6] none Transmitter time out counter TXUifram ON|OFf Enable sending UI frames in CONVERSE mode UIBeacon ON|OFf Xmits BTEXT when callsign in unproto string UILOc [1] ON|OFf Xmits LTEXT,L1text,L2text,L3text when Callsign in UI string UIMODe ON|OFf Immediate entry into CONMODE on power up Unproto call string (CQ) Path and address to send UI frames USers n = 0-10(1) Sets the numbers of streams (connections) Version [5] none Displays sign-on banner Xflow ON|OFf XON/XOFF Flow control enabled vs hardware XMitok ON|OFf Allow the transmitter to be keyed XOff n = 0-$7F ($13^S) Set the character to stop data from terminal XON n = 0-$7F ($11^Q) Set the character to start data from terminal